BeCOMS® – Error code and Error description

Information

The following messages,  displayed on the LCD of the Evaluator are possible

System Ready!

Standard message indicating that the system works and all measured values are in the permitted range.

BeCOMS-Error 04
First pulse sequence of incremental encoder – not connected

BeCOMS-Error 08
Second pulse sequence of incremental encoder – not connected

BeCOMS-Error 16
Synchronization signal of the incremental encoder – not connected

BeCOMS-Error 32
BeCOMS test-signal dead, check all connections

Information

The error codes may be summed up! For example, error code 20 means that the error codes 04 and 16 appeared together.

Possible combined codes are shown on the table 8.1 on the next page!

BeCOMS-Error 99
SRE-Sensor not connected

CPU Error xxx
A CPU error means an error from the EEPROM. This error appears also due to incorrect or incomplete parametrization. Should this error not be fixed after correcting the parameters and restarting please contact the manufacturer or the maintenance service, providing the error code.

01 xx Check parameters of CPU (…)
02 xx Check parameters of BeCOMS (…)

 Single codes
321684
Summed up codes12xx
20xx
24xx
28xxx
36xx
40xx
44xxx
48xx
52xxx
56xxx
60xxxx
Table 8.1 Code combinations