BeCOMS® – Technical Data of Slip Ring Encoder and Evaluator

In this chapter we will give you an overview of the main technical data, ordering options and a brief block-wiring diagram. For a detailed pin layout and technical drawings, please refer to Chapter 12 Appendix.

Power Supply:24V DC +30/-25%
Operating Current:
max. 2.0 A
Sensitivity: Adjustable in 5 steps
Relay-Outputs:Contact load for all relays:
max. 60V AC, 1A, 60VA / max. 60V DC, 1A, 60W
Alarm 1:
1 relay with 2 ground-free switch-over contacts, usually configured as main alarm.
Wire break protection with 33 kOhm resistors (standard)
Alarm 2:
1 relay with 1 ground-free switch-over contact, usually configured as pre alarm
Ready:
1 relay with 1 ground-free switch-over contact, energized if system is fault-free
Interface:Serial Interface:
• RS485 for standardized industrial, bidirectional communication
Communication Protocol:
• Modbus
• CAN Bus (optional)
User interface:LC Display 240*128 dots
1 LED red “Shutdown”
1 LED red “Pre-Alarm”
1 LED green “System Ready”
Connection cable:UL/cUL 12 x AWG 20 Style 2464/1581 300 V 80°C
Environment Conditions:Operational ambient temperature range:
0°C – 70°C for BCom Evaluator
0°C – 85°C for SRE
Storage ambient temperature range:
-25°C – 85°C
Protection:
IP65 for sensor
IP66 for Evaluator
(DNV-RU-SHIP Pt.4 Ch.9)
Nach oben scrollen