The following messages, displayed on the LCD of the Evaluator are possible
System Ready!
Standard message indicating that the system works and all measured values are in the permitted range.
BeCOMS-Error 04
First pulse sequence of incremental encoder – not connected
BeCOMS-Error 08
Second pulse sequence of incremental encoder – not connected
BeCOMS-Error 16
Synchronization signal of the incremental encoder – not connected
BeCOMS-Error 32
BeCOMS test-signal dead, check all connections

The error codes may be summed up! For example, error code 20 means that the error codes 04 and 16 appeared together.
Possible combined codes are shown on the table 8.1 on the next page!
BeCOMS-Error 99
SRE-Sensor not connected
CPU Error xxx
A CPU error means an error from the EEPROM. This error appears also due to incorrect or incomplete parametrization. Should this error not be fixed after correcting the parameters and restarting please contact the manufacturer or the maintenance service, providing the error code.
01 xx Check parameters of CPU (…)
02 xx Check parameters of BeCOMS (…)
| Single codes | |||||
| 32 | 16 | 8 | 4 | ||
| Summed up codes | 12 | – | – | x | x |
| 20 | – | x | – | x | |
| 24 | – | x | x | – | |
| 28 | – | x | x | x | |
| 36 | x | – | – | x | |
| 40 | x | – | x | – | |
| 44 | x | – | x | x | |
| 48 | x | x | – | – | |
| 52 | x | x | – | x | |
| 56 | x | x | x | – | |
| 60 | x | x | x | x | |
| Table 8.1 Code combinations | |||||