Troubleshooting

BeCOMS® – Data Sampling

As soon as the Evaluator is powered up, it starts the initial self check procedure and shows the READY status if all pre-set conditions are fulfilled. This self check procedure is carried out in a certain cycle. Regardless of the GREEN READY LED status of the Evaluator, if a working SRE is connected to it, the Evaluator samples the signals […]

BeCOMS® – Data Sampling Read More »

BeCOMS® – Syncronization of the BeCOMS® Sensor SRE with the firing TDC of the first cylinder

At the installation of the BeCOMS®  sensor SRE   an one time calibration of the incremental encoder has to be performed. This involves synchronising the neutral point of the incremental encoder with the firing Top Dead Center (TDC) of cylinder 1 by finding offset between them. It is important that the firing TDC is chosen at four-stroke engines, that is, when

BeCOMS® – Syncronization of the BeCOMS® Sensor SRE with the firing TDC of the first cylinder Read More »

BeCOMS® – Installation of Data Logger PC and BeCOMS® Software

Attention This chapter only applies if you are running a BeCOMS® Advanced or BeCOMS® Professional system! The Data_Logger  and  Data _Indicator  software comes pre-installed with the supplied Data Logger PC. The programmes must be configured correctly according to the system specific configuration on site after BeCOMS® commissioning. Please refer to BeCOMS® Data_Logger  and Data_Indicator manual for information.

BeCOMS® – Installation of Data Logger PC and BeCOMS® Software Read More »

BeCOMS® – SRE Mechanical Adjustments

The SRE must only be replaced by personnel from motcom GmbH or its authorized representatives. Installation and replacement of the SRE requires careful mechanical alignment as well as a precise synchronisation with the engine the SRE is installed to. To ensure the high level of reliability crucial for operation, two steps must be carried out very carefully: For the synchronization

BeCOMS® – SRE Mechanical Adjustments Read More »

BeCOMS® – Installation Position

The Slip Ring Encoder  is installed at the end of the crankshaft of the combustion engine via an engine specific adapter (refer to Fig.5.1 and Fig.5.2). The evaluator can be installed in the engine room near the engine or, alternatively, in the engine control room. The length of signal cables must not exceed 100 m. Example for an Installation

BeCOMS® – Installation Position Read More »

BeCOMS® – Installation

Installation and commissioning of BeCOMS®   must be conducted or supervised by personnel from motcom GmbH or its authorized representatives only. The installation procedure includes training for the site operation personnel. The commissioning data will be provided to the customer as part of the training for later reference. During the initial installation the current BeCOMS®  wiring will be adapted to the

BeCOMS® – Installation Read More »

BeCOMS® – Test Features

Menu level 1 Menu level 2 Menu level 3 Description Test Features   To get access to this menu, a PIN must be entered (see Table 2 on page 4.11). View and use test features of the Evaluator. (see Table 3 on page 4.12) Table 3 Test Features Details Menu level 1 Menu level 2 Menu level 3 Description Ready Relay

BeCOMS® – Test Features Read More »

BeCOMS® – Setup CPU

Menu level 1 Menu level 2 Menu level 3 Description Setup CPU   View and change BeCOMS® parameters. If the sublevel was entered (see Table 2 on page 4.11), pressing [Esc] restarts the Evaluator Table 2 Setup CPU Details Menu level 1 Menu level 2 Menu level 3 Description LCD brightness Brightness of Evaluator LC display in the range of 5

BeCOMS® – Setup CPU Read More »