BeCOMS® – Setup Parameter

Menu level 1 Menu level 2 Menu level 3 Description Setup Parameter   View and change BeCOMS® parameters. If the sublevel was entered (see Table 1 on page 4.9), pressing [Esc] restarts the Evaluator To get write access to these parameters, a PINmust be entered (see Table 2 on page 4.11) Table 1 Setup Parameter Details Menu level 1 Menu level 2 […]

BeCOMS® – Setup Parameter Read More »

BeCOMS® – SRE advanced infos 2

Menu level 1 Menu level 2 Menu level 3 Description  Displays advanced system values 2   ISa:       the current value at the A channel of incremental encoder (can be 1 or 0) ISb:       the current value at the B channel of incremental encoder (can be 1 or 0) ISs:        the current value at the 0 channel of incremental encoder (1 or 0)

BeCOMS® – SRE advanced infos 2 Read More »

BeCOMS® – SRE advanced infos 1

Menu level 1 Menu level 2 Menu level 3 Description  Displays advanced system values 1   TS1:     the value at the analog/digital converter of the first thermovoltage measurement channel TS2:     the value at the analog/digital con- verter of the second thermovoltage measurement channel TDC:        the calculated indicator of TDC (Top Dead Center) of the cylinder 1. If cylinder 1 is in TDC,

BeCOMS® – SRE advanced infos 1 Read More »

BeCOMS® graphical data indicator

Menu level 1 Menu level 2 Menu level 3 Description      Graphical data indicator   The displayed bars are: RPM:engine rotation speed in RPMTeff %ACA:effective value of thermovoltage in percents of AC alarm level Teff %DCA:effective value of thermovoltage in percents of DC alarm level Tsig %DCA:thermovoltage in percents of DC alarm level

BeCOMS® graphical data indicator Read More »