Troubleshooting

BeCOMS® – Optional Data Logger PC with Data_Logger Software

This chapter only applies if you are running a BeCOMS® Advanced or BeCOMS® Professional system! Otherwise, the following information can be ignored. The BeCOMS®   Data_Logger Software enables the user to: The Data_Logger Software handles up to six BeCOMS® systems. The Data_Logger Software does not replace the interconnection of the Evaluator with the engine safety and alarm system To ensure proper

BeCOMS® – Optional Data Logger PC with Data_Logger Software Read More »

BeCOMS® – Evaluator

The Evaluator (Fig.3.3) consists of a IP66 compliant, shock resistant metallic case, a  LCD, three LEDs (Shut-down, Pre-Alarm, System Ready),  four control  keys and one reset button . The Evaluator can be operated between 0-70°C and 0-80% relative humidity, suitable for installation close to the engine. It displays all measurement values and parameters and is used for diagnostics of the

BeCOMS® – Evaluator Read More »

BeCOMS® – Slip Ring Encoder SRE

The SRE (ref. Fig. 3.2) is the core part of the detection system as it detects the thermovoltage and rotational signal, ultimateley delivering the data for  monitoring of the engine. The SRE is adapted to a specific engine with a custom mounting board/flange. This ensures high compatibility across engine types and an easy dismount of the SRE for maintenance. The

BeCOMS® – Slip Ring Encoder SRE Read More »

BeCOMS® – Technical Data of Slip Ring Encoder and Evaluator

In this chapter we will give you an overview of the main technical data, ordering options and a brief block-wiring diagram. For a detailed pin layout and technical drawings, please refer to Chapter 12 Appendix. Power Supply: 24V DC +30/-25% Operating Current:max. 2.0 A Sensitivity:  Adjustable in 5 steps Relay-Outputs: Contact load for all relays: max. 60V AC, 1A, 60VA

BeCOMS® – Technical Data of Slip Ring Encoder and Evaluator Read More »

BeCOMS®- Scope of delivery

. BeCOMS® Slip Ring Encoder (SRE) Is installed with a vibration damper on the free end of the crankshaft via a mechanical adapter set Fig. 1.1 Slip Ring Encoder (SRE) • BeCOMS® EvaluatorServes as a local control and for evaluation and display of all values. It can transmit all data via RS485 interface to a computer running the BeCOMS® Data_Logger

BeCOMS®- Scope of delivery Read More »

BeCOMS®- Declaration of Conformity

EMC-Directives 2014/30/EU Manufacturer motcom® GmbHKurt-Schumacher-Str. 28-30D – 66130 Saarbrücken / GermanyPhone +49 681 8837904-0Fax: +49 681 8837904-19 We declare on our own responsibility, that the products Product description motcom® Bearing Condition monitoring Type designations BeCOMS® / BCom are in compliance with following norms: EN 55011:2018-05/CISPR 11:2015 mod.+A1:2017 EN 55032/CISPR 22 EN 61000-4-2, EN 61000-4-3, EN 61000-4-4 EN 61000-4-5, EN 61000-4-6,

BeCOMS®- Declaration of Conformity Read More »